A New Cascaded Switched-Capacitor Multilevel Inverter Based on Improved Series-Parallel Conversion with Less Number of Components

ABSTRACT

The aim of this study is to present a new structure for switched-capacitor multilevel inverters (SCMLIs) which can generate a great number of voltage levels with optimum number of components for both symmetric and asymmetric value of dc voltage sources. Proposed topology consists of a new switched-capacitor dc/dc converter (SCC) which has boost ability and can charge capacitors as self-balancing by using proposed binary asymmetrical algorithm and series-parallel conversion of power supply. Proposed SCC unit is used in new configuration as a sub-multilevel inverter (SMLI) and then, these proposed SMLIs are cascaded together and create a new cascaded multilevel inverter topology which is able to increase the number of output voltage levels remarkably without using any full H-bridge cell and also can pass the reverse current for inductive loads. In this case, two half bridges modules besides two additional switches are employed in each of SMLI units instead of using a full H-bridge cell which contribute to reduce the number of involved components in the current path, value of blocked voltage, the variety of isolated dc voltage sources and as a result the overall cost by less number of switches in comparison with other presented topologies. The validity of the proposed SCMLI has been carried out by several simulation and experimental results.

KEYWORDS

  1. Cascade sub-multilevel inverter
  2. Series-parallel conversion
  3. Self-charge balancing
  4. Switched-capacitor

SOFTWARE: MATLAB/SIMULINK

CIRCUIT DIAGRAM:

image001

Fig. 1. Proposed 17-level structure

 EXPECTED SIMULATION RESULTS

   image002

  • (a)
  • image003
  • (b)

Fig. 2. Steady states output voltage and current waveforms (a) in simulation Fig. 12. Transient states of output waveforms in simulation (b) in experiment ( 250V/div& 2A/div)

image004

Fig. 3. Transient states of output waveforms in simulation

  • image005
  •                                                                                             (a)                                   (b)

Fig. 4. Harmonic orders (a) output voltage (b) output current in simulation

image006

Fig. 5. Observed output voltage waveform at no-load condition (250V/div)

   image007

image008

 (a)

image009

image010

 (b)

Fig. 6. Capacitors’ voltage ripple waveforms for first case study (a) in simulation (b) in experiment (25 V/dev&50V/div)

 image011

image012

 

 image013

image014

 

image015

    

Fig. 7. Blocked voltage waveforms across switches of S1 (25V/div), S2 (100V/div), T1 (50V/div), T2 and T3 (100V/div) from left to right in the experiment

image016

                                                                                          (a)

image017     (b)

Fig. 8. Output voltage and current waveforms for (a) inductive load in experiment (250 V/div & 2 A/div) (b) sudden step load in simulation

image018

image019

(a)

image020

image021

(b)

Fig. 9. Observed capacitors’ current (a) in simulation (b) in experiment (2A/div)

image022

Fig. 10. (a) laboratory prototype (b) Output 49-level voltage and current waveforms in the experiment (250V/div & 2A/div)

 image023

image024

image025

image026

Fig. 11. Across voltage waveforms of capacitors in upper and lower stages of SCCs in proposed 49-level inverter (a) v C 1 lower stage (5V/div) (b) v C 2 lower stage (10V/div) (c) v C 1 upper stage(25V/div) (d) v C 2 upper stage(50V/div)

 

CONCLUSION

In this paper, at the first, a new reduced components SCC topology was presented which has boost capability remarkably and also can pass the reverse current for inductive loads through existing power switches. The voltage of all capacitors in this structure is balanced by binary asymmetrical algorithm. Next, a new sub-multilevel structure based on suggested SCC was proposed which can generate all of the voltage levels at the output (even and odd). In this case, the conventional output H-bridge cell used to convert the polarity of SCC units, has been removed, therefore number of required IGBTs and other involved components, are decreased. After that, an optimizing  operation was presented which could obvious the number of required capacitors in each of SCC units that participate in the cascade sub-multilevel inverter (CSMLI) to generate maximum number of output voltage levels with less number of elements. Moreover comprehensive comparisons were given which prove the differences between improved symmetric and asymmetric CSMLIs in contrast to some of recently presented topologies in variety aspects. Finally, to confirm the performance and effectiveness of proposed CSMLI, several simulation and experimental results have been presented.

REFERENCES

[1] J. Chavarria, D. Biel, F. Guinjoan, C. Meza, and J. J. Negroni, “Energy balance control of PV cascaded multilevel grid-connected inverters under level-shifted and phase-shifted PWMs,” IEEE Trans. Ind. Electron. vol. 60, no. 1, pp. 98–111, Jan. 2013.

[2] G. Buticchi, E. Lorenzani, and G. Franceschini, “A five-level single-phase grid-connected converter for renewable distributed systems,” IEEE Trans. Ind. Electron., vol. 60, no. 3, pp. 906–918, Mar. 2013.

[3] J. Rodriguez, L. J.Sheng, and P. Fang Zheng, “Multilevel inverters: A survey of topologies, controls, and applications,” IEEE Trans. Ind Electron., vol. 49, no. 4, pp. 724–738, Aug. 2002.

[4] L. G. Franquelo, J. Rodriguez, J. I. Leon, S. Kouro, R. Portillo, and M. A. M. Prats, “The age of multilevel converters arrives,” IEEE Trans. Industrial Electronic Magazine, vol. 2, no. 2, pp. 28–39, Jun. 2008.

[5] M. M. Renge and H. M. Suryawanshi, “Five-Level Diode Clamped Inverter to Eliminate Common Mode Voltage and Reduce dv/dt in Medium Voltage Rating Induction Motor Drives,” IEEE Trans. Power Electron., vol. 23, no. 4, pp. 1598-1607, Jul. 2008.